12 Installation (for qualified installers only)
Travis Industries 100-01142 4050114
Approved Vent Configurations
Restrictor
Position
A restrictor is built
into the appliance to
control the flow rate
of exhaust gases.
This ensures proper
flames for the wide
variety of vent
configurations.
Depending upon
the vent
configuration, you
may be required to
adjust the restrictor
position. The charts
for approved vent
configurations
describe which
position the vent
restrictor must be in.
To Adjust the Restrictor:
1
2
3
4
NOTE:
Position #1 is the fully open position
Determine a restrictor position (see the charts uner
"Approved Vent Configurations")
Remove the screw with a phillips screwdriver.
Rotate the adjustment plate clockwise until the correct index
hole is to the right of the pivot point.
Insert the screw into the correct index hole and tighten.
This restrictor is in
Position #5.
Rotate the adjustment
plate to change the
restrictor position.
Pivot Point
2
3
4
5
6
7
8
9
10
11
1
Adjustment
Plate
Index Holes
Screw
Diffuser Plate
Removal
Certain vent
configurations
require the diffuser
plate to be
removed. It is
located in the
firebox, behind a
baffle above the
burner. Refer to the
charts for approved
vent configurations
to determine if the
diffuser plate
requires removal.
a
c
d
5/16" Nutdriver
Remove the baffle.
Remove the
diffuser plate.
b
Replace the screws for the diffuser plate to seal
the holes in the firebox.
Replace the baffle.
/4" Nutdriver