A SERVICE OF

logo

Finalizing the Installation (for qualified installers only) 17
Travis Industries 100-01142 4050114
Finalizing the Installation
! Make sure the gas control valve is OFF and the heater is cool prior to conducting service.
1 Remove the glass (see page 19)
2 Install the log set and coals (see page 21).
! We recommend you purge the gas line at this time (with the glass removed). This allows gas to be
detected once it enters the firebox, ensuring gas does not build up.
3 Replace the glass (see page 19)
4 Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot. Start
the main burner. Leak test all gas joints again.
5 Check the pilot flame to make sure it looks like the illustration below. Adjust the pilot flame if necessary.
Standard
Screwdriver
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.