A SERVICE OF

logo

3 Product Description Compensator Operation
© 2007 Moog GmbH User Manual RKP-II (CA53461-001; Version 1.0, 10/07) 19
3.5.4 Load Sensing Compensator, J1
Load Sensing
Compensator, J1
Metering orifice:
Manually remote adjustable orifice valve or proportional orifice valve.
Pressure pilot valve:
Manually remote adjustable proportional pressure valve Q = 1–1.5 l/min.
Fig. 8: Load sensing compensator, J1
Pos. Description Pos. Description
1 Metering orifice for flow control 8 p spring
2 Safety valve p = p
max.
+ 30 bar 9 Locked adjustement screw
3 Control piston 2 10 Locknut for the adjustment screw
4 Control piston 1 11 Set at pilot valve
5 Adjustment of zero stroke 12 Set at metering throttle
6 Pilot pressure valve: 13 Orifice Ø 0.8 ... 0.9 mm
7 Valve spool