A SERVICE OF

logo

5 Transport and Storage Storing the Pump
© 2007 Moog GmbH User Manual RKP-II (CA53461-001; Version 1.0, 10/07) 31
Fig. 18: Transporting Multiple Pumps with Lifting Tackle
5.3 Storing the Pump
Storing the Pump
Preservation Conditions
Storage Conditions
Pre-Conditions:
Pump has been demounted. Ö Chap. "9.1 Demounting the Pump",
Page 55
CAUTION Damage to Property!
Storing the pump improperly may lead to property damage.
Store the pump as instructed and if necessary,
preserve it.
Storage Duration Preservation
up to twelve months not required
> 1 year required
Ö Chap. "5.4 Preserving the Pump", Page 32
Tab. 5: Preservation Conditions
Storage Duration Measures
> 1 year Visual inspection
Tab. 6: Storage Conditions