7 Operation Initial Pump Set-Up
© 2007 Moog GmbH User Manual RKP-II (CA53461-001; Version 1.0, 10/07) 45
Default Compensator Settings
∆p = 10 bar + 2 bar or ∆p = 20 bar + 2 bar
Hose for Control Line
The following information are recommended values:
Hose length approx. 800 mm
7.1.2.2 Load Sensing Compensator with p-T Control
Notch, R1
Default Compensator Settings
RKP-II 16–100: ∆p = 10 bar + 2 bar
RKP-II 140: ∆p = 13 bar + 2 bar
Hose for Control Line
The following information provides recommended values:
Hose length approx. 800 mm
7.1.2.3 Mechanical Stroke Adjustment
The information in this section also applies to: Ö Chap. "3.5.4 Load Sens-
ing Compensator, J1", Page 19
When high dynamics are required for flow control, orifice and control flow
volume, contact us to discuss application specific compensator
adjustments.
Pump Type NW [mm]
RKP-II 19 6
RKP-II 32, 45 8
RKP-II 63, 80, 100 10
Tab. 8: Nominal width for Control Line Hose
Information on the compensator:
Ö Chap. "3.5.5 Load Sensing Compensator with p-T Control Notch, R1",
Page 20
Pump Type NW [mm] D1 [mm] D2 [mm]
RKP-II 19, 32, 45 6 0.9 1.2
RKP-II 63, 80, 100 8 0.9 1.2
RKP-II 140 8 0.8 1.1
Tab. 9: Nominal width for Control Line Hose
Information on stroke adjustments:
Ö Chap. "3.5.6 Mechanical Stroke Adjustment, B1", Page 21
When adjusting the required flow volume, make sure that the stroke ring is
held tight between the two adjustment screws.
Upon delivery, the pump is set to V
max.
.