Arranging Multiple Pumps 6 Mounting
40 User Manual RKP-II (CA53461-001; Version 1.0, 10/07) © 2007 Moog GmbH
6.6.2 Attaching the Adapter Flange
Pre-Conditions:
Attaching the Adapter
Flange
The centering diameters of both the adapter flange and the add-on pump
match.
The dimensions of the through drive shaft match with the add-on pump.
The flange diameters of both the adapter flange and the add-on pump
match.
The connection surfaces are clean.
Procedure:
1. Attach the adapter flange to the add-on pump without damaging the
O-rings.
2. Bolt the adapter flange to the pump:
- Observe the tightening torques of the fasteners.
Ö Chap. "12.4 Tightening Torque", Page 65
For adding on a pump, the following adapter flanges are available:
Adapter flange SAE-A with 9-tooth shaft
Fig. 22: Adapter flange SAE-A with 9-tooth shaft
The adapter includes through drive shaft, seals (HNBR), intermediate ring for
RKP 63–140 and two fastening screws.
Profile
Thread
Shaft end
Thread
for add-on pump
Bolt
Flange Code: 82-2
Shaft Code: 16-4
Spline as per: ANSI B92.1 9T 16/32 DP Flat root side fit
Conditions for
attachment: RKP with heavy-duty through drive