12
2011 June
700a-NA
4-SPECIFICATIONS
IMPORTANT SAFEGUARD
5. Tape Width
36mm [1 1/2 inch] minimum to 48mm [2 inch] maximum
4. Tape
Scotch
®
pressure-sensitive fi lm box sealing tapes.
3. Operating Conditions
Use in dry, relatively clean environments at 5
o
C to 50
o
C [40
o
F to 120
o
F] with clean, dry boxes.
Note: Machine should not be washed or subjected to conditions causing moisture condensation on
components.
• To reduce the risk associated with fire
and explosion hazards:
− Do not operate this equipment in poten-
tially fl ammable or explosive environments.
WARNING
1. Power Requirements:
Electrical – 120 VAC, 60 Hz, 3.25 A
Pneumatic – 6.5 bar gauge pressure [95 PSIG], 2.5 SCFM
75 liter/minute @ 21° C., 1.01 bar maximum at maximum cycle rate.
A pressure regulator/fi lter is included.
The machine is equipped with two 1/6 HP gearmotors and comes with an 2.4 m [8 foot] standard neoprene
covered power cord and a grounded plug. Contact your 3M Representative for power requirements not listed
above. Contact your 3M Representative for power requirements not listed above.
2. Operating Rate:
Belt speed is 0.5m/s [100 F.P.M.]
Actual production rate is dependent on operator's dexterity. Boxes must be 18 inches (457mm) apart minimum.