Agilent E4411B Specifications and Characteristics
Amplitude
Agilent E4411B Specifications and
Characteristics
Specifications Supplemental Information
Spurious Responses
50
Second Harmonic Distortion
Input Signal
2 MHz to 750 MHz < 75 dBc for 40 dBm signal
at input mixer
a
+35 dBm SHI (second
harmonic intercept)
Third Order Intermodulation
Distortion
2 MHz to 10 MHz +14.5 dBm TOI (third order
intercept), typical
10 MHz to 1.5 GHz < 75 dBc for two 30 dBm
signals at input mixer
a
and
>50 kHz separation.
+7.5 dBm TOI
Other Input Related Spurious
30 kHz offset 1200 MHz < 65 dBc for 20 dBm signals
at input mixer
a
1.5 GHz.
Offset >1200 MHz < 45 dBc for 20 dBm signal
at input mixer
a
1.5 GHz.
Noise Floor Degradation
Input frequency =
1210.7 MHz ± RBW
< 62 dBc for 45 dBm signal
at input mixer
a
a. Mixer Power Level (dBm) = Input Power (dBm) Input Attenuation (dB).
Specifications Supplemental Information
Spurious Responses
75 Ω, (Option 1DP)
Second Harmonic Distortion
Input signal
2 MHz to 750 MHz < 75 dBc for +8.75 dBmV
signal at input mixer
a