O P E R AT I O N
- E L E C T R O N I C C O N T R O L
POWER INDICATOR LIGHT
UP/DOWN
A
RROWS
ON/OFF POWER KEY
LOCK INDICATOR
L
ED DISPLAY
H
EAT INDICATOR
L
IGHT
ON/OFF KEY
Press the on/off key once and the power indicator light will
illuminate. Press and hold the on/off key until the LED
display turns off (at least three seconds) and on/off indicator goes
out.
UP/DOWN ARROW KEY
The up and down arrow keys are used for a variety of settings
when selecting the holding temperature. If an arrow key is pressed
and released the display will show the current set temperature for
two seconds. If an arrow key is held (at least eight seconds), the
value will change at a rapid rate. If the arrow key is pressed and
released in rapid succession, the set temperature will change by
increments of one degree.
ENABLE/DISABLE BEEPER
A beeper sounds when an error code is displayed.
To choose between beeper on and beeper off mode, the
control must be OFF, then press and hold the down arrow
key until either "ON" or "OFF" is shown in the LED display.
Release arrow key when desired mode is displayed.
FAHRENHEIT / CELSIUS
With the control OFF, to choose between Fahrenheit and Celsius,
press and hold the up arrow key until either °F or °C is shown
in the LED display. Release key when desired setting is displayed.
The control has a four-digit LED display. When the display
is ON, it will show current holding temperature, as well as
diagnostic information.
CONTROL LOCK
The warmer controls can be locked so that no changes can
be made to the set temperature.
To lock the display, press and hold the ON/OFF key and
the Up Arrow key at the same time. The lock indicator will
illuminate. When the lock indicator is illuminated, additional
programming will not be functional other than the key
sequence required to unlock the panel.
To unlock the display, press and hold the ON/OFF key and
the Down Arrow key at the same time. The lock indicator
will extinguish. The panel keys will resume normal function.
1. Preheat at 200°F (93°C) for
30 minutes.
Press the ON key, and set the temperature
to 200°F (93C°) by using the UP/DOWN
arrow keys. Allow a minimum of 30
minutes preheating time before loading the
drawer warmer with food. The LED heat
indicator light will go “OUT” after
approximately 30 minutes preheat time, or
when the air temperature inside the unit
reaches the temperature set by the operator.
2. Load with pans of hot food only.
The purpose of the warmer is to maintain
hot food at proper serving temperature.
Only hot
food should be placed into the
unit. Before loading with food, use a food
thermometer to make certain all products
are at an internal temperature range of
140° to 160°F (60° to 71°C). Any food
product not within the proper temperature
range should be heated before loading into
the unit.
3. Reset the control to 160°F (71°C).
Check to make certain the drawer is
securely closed, and reset to 160°F (71°C)
by using the UP/DOWN keys.
THIS WILL NOT NECESSARILY BE THE
FINAL SETTING.
The proper temperature range will depend
on the type and quantity of product. When
holding food for prolonged periods, it is
advisable to periodically check the internal
temperature of each item with a food
thermometer to assure maintenance of the
proper temperature range of
140° to 160°F (60° to 71°C).
°F /°C