Alto-Shaam AR-7H ELECTRONIC CONTROL Oven User Manual


 
S E R V I C E
AR-7H Hot Holding Rotisserie Companion Operation & Care Manual 15
T R O U B L E S H O O T I NG GU I D E - EL EC T R O N I C CO N T R O L
T R O U B L E S H O O T I NG GU I D E - M A N U A L C O N T R O L
TROUBLE POSSIBLE CAUSE REMEDY
Unit does not operate Insufficient power supply
Defective power cord or plug
Defective power switch.
Defective thermostat.
Check power source.
Check and replace if necessary
Check and replace if necessary.
Replace thermostat and calibrate.
Cannot control temperature. Defective thermostat.
Grounded element.
Replace thermostat and calibrate.
Replace element (Check element to
ground Ohm Element @ 27.7 Ohms)
Temperature gauge readout incorrect. Defective temperature gauge
Calibration off.
Replace temperature gauge.
Calibrate according to instructions
found on page 9.
Error
Code Description/Results
Possible Cause
Service Required
E-10 Air Sensor Fault (shorted)
Inope rative Oven
Air sensor is shorted. Air sensor defective?
Detach the sensor from the terminal block. Use an Ohm meter to measure
the resistance of the sensor. Check sensor at 32°F (0°C) using a container of
ice water. If Ohm reading is 100, replace display. If Ohm reading is not 100,
replace sensor.
E-11 Air Sensor Fault (open)
Inope rative Oven
Air sensor is open or connection failure. Air sensor defective?
Detach the sensor from the terminal block. Use an Ohm meter to measure
the resistance of the sensor. Check sensor at 32°F (0°C) using a container of
ice water. If Ohm reading is 100, replace display. If Ohm reading is not 100,
replace sensor.
E-30 Under temperature
Oven will not reach set temperature
Oven door closed? Door gasket need replacement? Preheat skipped?
Oven overloaded or has frozen product? Defective air sensor or probe?
Defective solid state relay? Bad wire connections or open heating cable?
Is the high limit switch tripped? If none of the above, call service.
E-31 Over temperature
Oven will shut down
Shorted cable? Defective solid state relay? Defective air sensor?
If none of the above, call service.
E-80 EEPROM - Function data error
Inope rative Oven
Contact Service.
E-82 EEPROM - Calibration data error
Inope rative Oven
Contact Service.