Alto-Shaam ASF-75E Fryer User Manual


 
Electric Fryer Operation & Care Manual • 39
DELUXE CONTROL OPERATION
PROGRAMMING THE CONTROL
“FILTER CNT”
The filter count program allows the operator to change the number of processed fry
loads within a range of 5 to 15 before the monitor notifies the operator to service the oil/
shortening. The factory default is set at 15 loads. THE “FILTER” MONITOR PROGRAM
MUST BE ACTIVATED IN ORDER TO MAKE THE “FILTER CNT” PROGRAM FUNCTIONAL.
Press the Up or Down arrow keys to scroll until “FILTER CNT” appears in the display. Press
the Right4arrow key to enter the program. Display stops flashing. Press the Up
or Down arrow keys to until the desired number of processed loads appears in the
display.Whenthedesiredsettingappears,presstheRight4 arrow key to accept the
selection. Display flashes. Press the Down arrow key to advance the control to the
next programming function.
“MAX TIME”
“MAX TIME” provides notification when the temperature of the oil is
lower than the set-point temperature. The factory set default is 3 minutes
and should not be adjusted by the operator. Press the down arrow
key to advance the control to the next programming function.
“HI TEMP”
“HI TEMP” allows the operator to trigger an automatic fryer shut-down at a specified
oiltemperaturewithinarangeof250°Fto450°F(121°Cto232°C).Thissafetyfeatureis
provided in the event the actual oil temperature exceeds the oil set-point
temperature due to equipment malfunction. The factory default is set at
450°F(232°C).
Press the Up or Down arrow keys to scroll until “HI TEMP” appears in the display. Press
the right4arrow key to enter the program. Display stops flashing. Press the Up or
Down arrow keys to scroll until the desired shut-down temperature appears in the
display.Whenthedesiredtemperatureappears,presstheright4 arrow key to accept the
selection. Press the down arrow key to advance the control to the next
programming function.
3:00
Max Time
LoTemp
HOT
450° F
Hi Temp
15