QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 3.
CLEARANCE REQUIREMENTS
BACK: 6" (152mm) TOP: 6" (152mm)
SIDES: 4" (102mm) minimum at both sides.
18" (457mm) MiNiMuM clearaNce
froM heat produciNg equipMeNt.
INSTALLATION REQUIREMENTS
Unit must NOT be tipped on its side
at any time.
Tipping will cause damage to the unit
and void the warranty.
One (1) Floor Drain: 1/2" (12,7mm) diameter
— Appliance must be installed level.
— The appliance must not be installed in any area
where it may be affected by steam, grease, dripping
water, extreme temperatures, or any other severely
adverse conditions.
In order to maintain standards established by the
National Sanitation Foundation, all counter mounted
equipment must be sealed to the counter with a NSF
listed silicone sealant.
CAUTION
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
5-Year Limited
Warranty on
self-contained
compressor
Effective from date of
shipment. (excludes labor)
Position the Quickchiller
to allow sufficient air
ventilation through the
condensing unit(s). The
rear of unit should be no
closer than 6" (152mm)
to any wall or structure.
Avoid installing the
chiller immediately
adjacent to fryers,
charbroilers, or any other
equipment producing
grease laden air; heat
producing equipment
such as ovens and
ranges; and steam discharging equipment such
as steamer ovens and kettles. Do not locate the
Quickchiller in direct sunlight.
Allow sufficient front clearance for serviceability
and for easy maneuvering of food trolleys in and
out of the cabinet.
INSTALLATION
Prior to moving the Quickchiller to the installation
site, check the dimensions of doors, passageways, and
ceiling heights in the areas through which the cabinet
must be moved. Also check the turning radius if the
cabinet must be moved around an existing structure.
The use of a fork lift or pallet lift truck is required for
moving and leveling most Quickchiller models.
NOTE: In certain instances, it may be necessary
to remove doors and door hardware to
negotiate tight spaces.
®
DANGER
IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH,
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
INSTALLATION
SITE INSTALLATION