Amana AKGD3050 Cooktop User Manual


 
11
The installation of appliances designed for
manufactured (mobile) home installation must conform
with Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, or when such
standard is not applicable, the Standard for
Manufactured Home Installation, ANSI225.1/NFPA
501A-Latest Edition, or with local codes or the standard
CAN/CSA-z240MH, “Mobile Homes”, and with local
codes where applicable.
Installation of this product must conform with local
codes or in absence of local codes, with current
Canadian Gas Installation Code CAN/CGA-B149.2.
Use a dedicated 120 volt, 60 hertz, 3-prong receptacle
protected by a 15-amp circuit breaker or time delay
fuse. A qualified electrician should confirm the outlet is
properly grounded. Cooktop includes 4-foot power cord
attached to bottom of cooktop at back, right corner.
If a 2-prong outlet is encountered, cooktop owner must
replace outlet before using cooktop. Do not cut off cord
or remove grounding prong.
Neutral
Ground
L1
0
V.A.C.
115
± 12
V.A.C.
115
± 12
V.A.C.
Neutral
side
Round
grounding
prong
Standard 120 Volt, 60 Hertz
Gas Supply Location
Locate gas supply so manual shutoff valve is
accessible after installation. Gas supply can be
installed in adjacent cabinet or behind access panel.
Junction Box Location
Power supply enters cooktop in right, rear corner.
Junction box must be located within 30 inches of power
supply entry point. Locate junction box within shaded
area.
A
B
C
L
A—12 inches
B—4½ inches (From top of countertop)
C—24 inches
C
L
—Center line
Junction Box Location