Antunes, AJ VS-200aSb Electric Steamer User Manual


 
10
VARIETY STEAMER
P/N 1010649 Rev. E 03/07
OPERATION
Operator Controls
ROCKER SWITCH (POWER ON/OFF)
When the Rocker Switch is in the ON position, the
control board is activated and the green light on the
front panel lights up. A thermostat senses generator
temperature. If the generator temperature is below
350° F (176° C), power is applied to the generator until
setpoint is reached. The generator is constantly moni-
tored and power is regulated to maintain temperature
setpoint of 380° F (193° C).
YELLOW AND GREEN LIGHTS
The green light comes on when the Rocker Switch
(Power On/Off) is turned on. The green light is not lit
during the steaming cycle.
The yellow light comes on during the steaming cycle.
When the steaming cycle is complete, the yellow light
turns off, and an audio alarm sounds for 3 seconds.
CONTROL KNOB
The control knob setting determines the length of the
steaming cycle. Each number on the panel behind the
knob represents a ten second interval (1=10 sec; 2=20
sec; 3=30 sec; etc.) up to 130 seconds.
Example: During the steaming cycle, with the control
knob set to 3, the solenoid valve opens once every 10
seconds, applying 3 total shots of water that is con-
verted immediately into steam for the product.
NOTE: Each shot of steam is approximately 3/4 oz.
(25 milliliters) of water.
OPERATE SWITCH
When the operate button is pressed and released, Line
Voltage is supplied to the solenoid valve, the solenoid
valve opens, and water sprays onto the heated steam
generator. The water flashes immediately into live
steam and is forced up through the Black Manifold
Plate orifices.
LOCK LEVER
When in the full forward (towards operator) position,
the lock lever secures the Black Manifold Plate onto
the Steam Generator. Moving the lock lever to the full
rearward position unlocks the Black Manifold Plate,
allowing it to be removed for cleaning or servicing.
POWER
1
2
3
4
5
6
7
8
9
10
11
12
13
READY
STEAM
Green
Light
Yellow
Light
Operate
Switch
Lock Lever
Knob
Control
Knob
Rocker Switch
(power on/off)
Audio
Signal
Figure 3. Operating Controls
Lock Lever Knob
Locked Position
Figure 4. Lock Lever
HI-LIMIT THERMOSTAT
If the generator should overheat for any reason, the
Hi-Limit thermostat opens (trips) and cuts off power to
the generator. To reset this Hi-Limit, turn the unit off,
unplug the power cord, disconnect the rear water line
quick disconnect insert, and allow the unit to cool for 45
minutes. Place unit upside down and remove the four
(4) Control Panel screws (Figure 4). Carefully lift the
Control Panel upward and lay it on its side. Fully press
the red Hi-Limit Reset Button. Reassemble the unit. If
the Hi-Limit requires continuous resetting, contact your
Authorized Service Agency.