TROUBLESHOOTING (continued)
Problem Possible Cause Corrective Action
Unit heats but there is little
or no steam produced
and/or
The product requires more
steaming than usual.
(Continued)
Insufficient or excessive calcium/mineral
buildup on generator surface.
Verify that a thin layer of calcium/mineral
deposits is present on the Generator sur
-
face. Refer to the Maintenance section of
this manual.
Black Manifold O-ring is worn, damaged,
or missing.
Replace the Black Manifold O-ring if worn,
damaged, or missing.
Low Generator temperature. Verify Generator surface temperature is at
least 380° F (193° C),
Steam leaks out of the
sides of the unit.
Black Manifold O-ring is damaged or
missing.
Replace the Black Manifold O-ring if worn,
damaged, or missing.
Black Manifold is difficult
to remove or re-install
onto the Generator.
Black Manifold not being removed and
cleaned daily as required.
Remove and Clean the Black Manifold
Daily according to the Maintenance section
of this manual.
Black Manifold O-ring is damaged or
worn.
Replace the Black Manifold O-ring if dam
-
aged or worn.
Black Manifold O-ring is not being lubri
-
cated daily with Petro Gel.
Lubricate the Black Manifold O-ring daily
according to the Maintenance section of
this manual.
Unit floods over night
and/or continues to steam
even when just in ready
mode.
Solenoid valve is being held open by
debris from the building’s water line pip-
ing.
Attempt to flush the debris out of the valve
by operating the unit on a number of cycles
and then letting it rest. If the unit still
leaks, contact your maintenance person or
Authorized Service Agency.
There is no pre-strainer/filter on the water
line just before the unit.