When using electrical products, basic precautions should always be observed, including the following:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Circuit: A separate circuit (not to supply any other electrical devices) is required as follows: For units
equipped with a pump motor only, a 110/120 VAC 15 Amp circuit is required. Wire coding is black [hot], white
[neutral] and green (or bare copper for ground).
3. GFCI: A Ground Fault Circuit Interrupter must be installed in the circuits which bring power to the
whirlpool; do not omit. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset
button. Power should be restored. If the GFCI fails to operate in this manner, there is a ground current flowing,
indicating the possibility of an electric shock. Do not use this unit. Disconnect the unit and have the problem
corrected by a licensed electrician before using.
4. Grounding: Motors have a three prong electrical plug requiring a black [hot], white [neutral] and
green wired circuit.
5. Bonding: A pressure wire connector is provided on the exterior of the motor within this unit to permit connection
of a No. 8 AWG solid copper bonding conductor between all electrical equipment, as needed to comply with local
requirements.
6. Wall Switch: A remote wall switch is required by many state codes. It must not be within 5 ft. (1.5 m) reach of a
bather while standing in the tub and it must be mounted at a height to be out of the reach of small children. The
remote switch should not be further than 10 ft. (3.0 m) away.
7. Integral On/Off Switch: For a Symphony whirlpool supplied with a motor that has an integral on/off switch -- Make
certain the air tube that is connected to the motor is also connected to the on/off button nipple under the deck in
order for the system to function.
All local, state and national electrical codes must be observed by a licensed electrician in connecting power to the
Aquatic whirlpool.
INSTALLATION INSTRUCTIONS
ELECTRICAL INSTALLATION: