Bally Refrigerated Boxes Refrigerators/Freezers/Warmers Refrigerator User Manual


 
- 6 -
INSTALLING CONDENSATE EVAPORATOR
No floor drains or plumbing connections are required since all models use an
automatic condensate water evaporating system. All designer line models utilize a
unique hot gas condensate water evaporating system which is completely self-
contained and no further assembly or maintenance is required (these models are
recognized by their evaporator coil which is located out of the food zone in an
insulated plug-box housing next to the condensing unit). All value line models are
supplied with an electric condensate evaporator pan and mounting bracket packed
in the accessory carton. To install the condensate pan on value line models only,
remove both mounting screws located on the bottom of the cabinet back and install
the mounting bracket on the case bottom as shown in figure 4. Slide the
condensate pan onto the bracket, install the drain tube into the pan making sure it
is not blocked or kinked, and plug the ten foot power cord into the receptacle
labeled "vaporizer" located on the case top electrical box.
IMPORTANT NOTE: It is extremely important to be sure that the
condensate pan is plugged into its correct receptacle labeled "vaporizer" and
that the condensing unit is plugged into its correct receptacle labeled
"condensing unit".
FIGURE 4
CONDENSATE EVAPORATOR INSTALLATION