Breville BES900 Coffeemaker User Manual


 
18 19
OPERATING YOUR BREVILLE DUAL BOILER™OPERATING YOUR BREVILLE DUAL BOILER™
RESETTING DEFAULT SETTINGS
The machine has the following
default settings:
1. Temperature – 93°C
2. Pre-Brew Infusion –
PP60, PT5 seconds
3. Auto Start - OFF
4. Auto Start Time - 7.00am
5. Audio - LO
To reset machine to original default
settings, first ensure machine is
switched off. Press and hold 1 CUP &
2 CUP buttons and then press the
POWER button.
The LCD will display REST. All
programmed settings will be reset to the
original default setting.
The machine will return to
STANDBY mode.
ADVANCED FUNCTIONS
Press & Hold - 1 CUP
Press & hold 1 CUP button to deliver water
to the group head at full pump pressure and
release button to stop extraction.
Press & hold 1 CUP by-passes the
pre-infusion step and delivers water to the
group head at the full 9 bar pressure. This
function can be used when purging the
group head.
Press & Hold - 2 CUP
Press & hold 2 CUP button to deliver water
to the group head at full pump pressure and
release button to stop extraction.
Press & hold 2 CUP by-passes the
pre-infusion step and delivers water to
the group head at the full 9 bar pressure.
This function can be used when purging
the group head.
Press & Hold - MANUAL
Press & hold the MANUAL button to
deliver water to the group head at low
pre-infusion pressure. When MANUAL
button is released, water will continue at
the full 9 Bars of pressure. Press MANUAL
button again to stop extraction .
This function can be used to manually
control the pre-infusion duration.
ADVANCED PROGRAMMING
Pre-Infusion Programming
Press UP and DOWN arrows together to
enter PRE-INFUSION programming mode.
Press MENU button to move between
Pre-infusion Duration and Power.
Pre-Infusion Duration
The LCD will display the current
Pre-Infusion Duration.
Press UP or DOWN arrow to vary time.
We recommend a range of between 5-15secs
as being optimum.
Pre-Infusion Power
The LCD will display current
Pre-Infusion Power.
Press UP or DOWN arrows to vary power.
We recommend a range of between
50-65 as being optimum.
Press EXIT to return to STANDBY mode.
Temperature Unit - ˚C/˚F
Ensure machine is switched Off.
While holding DOWN arrow, press the
POWER button. The LCD will display the
current temperature unit (˚C or ˚F).
Press UP or DOWN arrow to select desired
temperature unit.
Press EXIT to return to STANDBY mode.
Machine Audio
Machine Audio refers to the volume level of
the ‘beeps’ heard.
HI - high volume
LO - low volume
OFF - no volume
Ensure machine is switched Off.
While holding UP arrow, press the POWER
button. The LCD will display the current
audio volume.
Press UP or DOWN arrow to select
desired volume.
Press EXIT to return to STANDBY mode.