PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
SET PULSE BREW:
This function allows the operator to program the
brewer to "pulse” the sprayhead flow on and off dur-
ing a brew cycle (start and stop the flow of water out
of the sprayhead). This feature allows the ability to
“fine-tune” the brewer for specific flavor profiles. Pulse
brewing can be set up for any and all batches.
a) 1st ON TIME - This time is the duration from when
the pad is pressed to when the desired water
level in the funnel is reached. (Soaking the
grounds)
b) OFF-TIME - This time is the duration from when
the water in the funnel reaches the desired ON
TIME level to when it drains out of the funnel to a
desired lower level.
c) LAST ON-TIME- This time is the duration from when
the water in the funnel drains down to the lower
level to when it fills the funnel to a desired higher
level. (Soaking the grounds).
These three times can be set two different ways.
The first is by observing the flow of water for on and
off times. This is accomplished by utilizing the SET
BY EXAMPLE screen and following the subsequent
steps under that function.
The other allows the actual times to be entered
for each of the settings. This is done by utilizing the
ENTER TIMES screen and following the subsequent
steps under that function.
Either of these methods can be used to set the
pulse brew for each batch.