DRIP TIME (now displayed on "non" funnel lock units
as well)
This function allows the setting or modification of
the funnel locks to stay engaged after the end of a
brew cycle. This ensures that the funnel cannot be
removed until after the liquid has emptied out of the
funnel.
Procedure to modify drip times:
Range: OFF to 10 minutes for all three batch sizes.
NOTE: If the brewer is already in the DRIP TIMES
screen, it is not necessary to follow steps 1 through 10
in this section, but proceed directly to step 11.
1. Press and hold the ® pad until the display reads
SET NEW RECIPES. Release the ® pad. Press the
® until the display reads REVIEW RECIPES.
2. Press YES to proceed. The display should now
read NO-NAME LEFT, along with MODIFY, SHOW
and NEXT.
3. Press and release NEXT to advance to the desired
coffee name to be modified.
4. Press and release MODIFY. The display should
read BREW OZ.
5. Press and release DONE. The display should read
3 BATCHES DONE?.
6. Press and release YES. The display should now
read % BYPASS.
7. Press and release DONE. The display should read
3 BATCHES DONE?.
8. Press and release YES. The display should now
read SET PULSE BREW.
9. Press and release NO. The display should now
read SET PREINFUSION.
10. Press and release NO. The display should now
read DRIP TIME, along with either the word OFF,
or a time will be showing. A batch light should also
be blinking.
11. Using the (-) and (+), set the amount of time from
when the brew solenoid shuts off to when drip-out
occurs for that batch size.
P2297