Page 35
FACTORY DEFAULTS
This function allows the operator to erase all of the
previously entered recipes and ad messages. Factory-
set default values will replace all previous settings.
Procedure to set factory defaults:
1. Press and hold the ® pad until SET NEW RECIPES
appears. Release the ® pad. Press and release ®
until the display reads FACTORY DEFAULTS.
2. Pressing NO in this screen will revert to the MAIN
SCREEN. Press YES to replace the defaults. This
advances to WILL REPLACE ALL BREWING SET-
TINGS. This screen will alternate with ARE YOU
SURE?.
3. Pressing NO in the confirmation screen will revert
to MAIN SCREEN, without resetting the brewing
setups to the defaults. Press YES to load the
defaults. This will then revert to the MAIN SCREEN,
and the factory default values will replace all
previously entered values. It will NOT reset the
summation Brew counter.
P2312
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
FACTORY DEFAULT VALUES
Brew Lockout YES
BREW VOLUMES:
Small Batch 64 oz.
Medium Batch 128 oz.
Large Batch 192 oz.
BYPASS PERCENTAGE:
Small Batch 0%
Medium Batch 0%
Large Batch 20%
PULSE BREW TIMES:
Small Batch :20 (1st on)- :15 (off)- :05 (last on)
Medium Batch 1:00 (1st on)- :10 (off)- :20 (last on)
Large Batch :40 (1st on)- :15 (off)- :20 (last on)
PREINFUSION TIMES:
Small Batch DISABLED
Medium Batch DISABLED
Large Batch DISABLED
DRIP OUT TIMES:
Small Batch 1:00
Medium Batch 1:30
Large Batch 2:00
ENABLE ADS YES
BREW TEMPERATURE 205˚F (96˚C)
READY TEMPERATURE 195˚F (91˚C)
REFILL 0 - 155
SPRAY (OZ/MINUTE) 53
BYPASS (OZ/MINUTE) 48
FUNNEL DETECT YES
35058 121102