"EASY PULSE BREW" times:
Min: Base brew time + 40 seconds
Max: Base brew time + 3:00 minutes
DRIP TIME 0:30
(-) DONE (+)
0 REFILL 155
(-) DONE (+)
ENABLE CLEAN
NO DONE YES
SET PULSE BREW ?
NO YES
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
ADJUSTMENTS & OPTIONAL SETTINGS (CONT.)
This function allows the sprayhead to “pulse” on and off dur-
ing a brew cycle. These times can be set two different ways.
The first is by setting the total brew time in the "EASY PULSE
BREW" screen. The other option allows the actual times to be
entered in the "MANUAL PULSE BREW" screen.
Adjusts the DRIP TIME (time from end of sprayhead flow to
when liquid stops dripping from the funnel). When the brew
cycle is complete, the display will show "DRIPPING" and will
countdown the time until the funnel empties.
RANGE: "OFF" or 0:05 to 4:00 minutes
Set the time before a cleaning alert will be displayed.
RANGE: 1 to 30 days
Enables the mode function and sets the idle time. Then choose
to have the tank heater(s) turn off, or reduce the tank temp to
(140° F) or (60° C) once the set idle time has expired.
Range: 0.5 to 24.0 hrs
Enables the "FRESHNESS ALERT!" message and sets the
expiration time. The expiration time is the amount of time the
product is allowed to sit in the server before an alert message
is displayed.
Range: 0.5 to 4.0 hrs
Adjusts the sensitivity of the refill circuit. Water in different
geographical locations can have different conductivities. Make
sure the water in the tank is touching the refill probe. NOTE:
Always make sure that the # on the right is larger than the #
on the left when water is contacting the tank refill probe.
NOTE: This will overwrite settings in "BREW METER".
Sets the amount of time a warmer will remain on after being
turned on. Each warmer has an independent timer and is af-
fected by its corresponding switch. NOTE: The lower "Brew"
warmer timer is restarted when brew switch is pressed. Range:
15mins to 6.0 hrs in 15 min increments.
Enabl EnergySavr
NO DONE YES
ENABL WARMER OFF
NO DONE YES
EnableFreshTimer
NO DONE YES