Bunn Axiom Coffeemaker User Manual


 
Page 16
PROBABLE CAUSE REMEDYPROBLEM
TROUBLESHOOTING (cont.)
Weak beverage. BUNN paper filters should be
used for proper extraction
For coffee, a sufficient quantity
of fresh drip or regular grind
should be used for proper ex-
traction.
A BUNN sprayhead should be
used to properly wet the bed of
ground coffee in the funnel
The BUNN paper filter should
be centered in the funnel and
the bed of grounds leveled by
gently shaking.
Place empty funnel on top of an
empty server (not in the funnel
rails). NOTE: Do not remove
sprayhead!
WARNING: HOT WATER
Press brew. Check water tem-
perature immediately below the
sprayhead with a thermometer.
Recommended reading should
be at least 195°F (90°C).
Consider adjusting brew vol-
ume, and/or BREW METER.
1. Type of paper filter
2. Coffee
3. Sprayhead
4. Funnel Loading
5. Water temperature
6. Incorrect recipe
41154 041708