Bunn Axiom Coffeemaker User Manual


 
Page 13
FACTORY DEFAULTS
NO YES
SERVICE TOOLS ?
NO YES
BREW COUNTERS ?
NO YES
CALIBRATE FLOW ?
NO YES
SPRAY OZ/M: 25.0
(-) DONE (+)
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
View or enter the actual flow rate coming out of the sprayhead.
This is used to tell the internal controller how fast the water
is flowing. Use the "CALIBRATE FLOW" screen to obtain the
most current flow rate.
Range: (3.0 to 75.0 oz) or (100 to 2200ml)
This function provides a 60 second test mode to capture
water from the sprayhead. This measurement will then give
you the numbers to enter into the "SPRAY OZ/M: xx" screen
above.NOTE: Should be performed after deliming and/or
changing sprayhead. (Will not display when "BrewLogic"
is enabled)
Tracks the total number of brew cycles completed. There is one
reset-able counter, and one life counter that is not reset-able
Allows the testing of individual components and the ability to
check the membrane switches for proper function. (Diagnostic
tool for troubleshooting purposes only)
Reset ALL of the previously entered brew settings, ad mes-
sage, calibrations, etc. Factory-set default values will replace
ALL previous settings.
NOTE: Items not affected; Service #, Password, Language,
Units, Asset #, Counters and Serial Number.
ENABLE ENERGY SAVER - NO
ENABLE FRESH TIMER - NO
ENABLE WARMER OFF - NO
REFILL - 155
SPRAY 25.0 oz/M (739ml/M)
Software Version 1.07 & above
BrewLogic OFF
INITIAL FACTORY DEFAULT VALUES
Brew Lockout NO
BREW 64 OZ (2.0L)
BREW METER 1
ENABLE ADS NO
PASSWORD 0
Language English
Units English
SET TEMP 200° F (93° C)
SET READY 195° F (90° C)
ENTER ASSET # - 0
PULSE BREW - DISABLED
DRIP TIME - 0:30
ENABLE CLEAN - NO