Bunn Axiom Coffeemaker User Manual


 
Page 4
ADJUSTMENTS & PROGRAMMING
MAIN SCREEN
BREW LOCKOUT
This function allows the operator to prevent
or allow brewing if the water temperature is less
than the set READY temperature.
To access this function screen press and hold
the right hidden switch. Release when the display
reads: "BREW WIZARD" it will then read:
Press here
for NO
Press here
for DONE
Press here
for YES
PROGRAM FUNCTIONS - BREW WIZARD
PROGRAMMING THE BREWER
The programming of the brewer is divided into two levels. Brewing adjustments are in "BrewWiz-
ard". Service functions are accessed in Level 2.
The following function screens are in order of appearance. Each screen will have instructions on
how to access, and the procedures to program the various functions of the brewer.
IMPORTANT PROGRAMMING NOTES
- READ CAREFULLY -
To exit the programming mode at any time, press and release "ENABLE BREW ON/OFF" switch
located on the front switch panel. The display will return to the MAIN SCREEN.
If none of the five programming switches are pressed within one minute during the setup of the
brewer, the programming of the function screen that is being set will be exited and the display will
return to the MAIN SCREEN.
Always remember to place an empty server and funnel under the sprayhead when operating the
brewer during the set-up of PULSE BREW, CALIBRATE FLOW and testing the brew valve in SER-
VICE TOOLS/TEST OUTPUTS.
BREW LOCKOUT?
NO DONE YES
READY TO BREW
WATER TEMP: 200°
PROGRAMMING LOCKOUT SWITCH
(Mounted on main control board)
This switch can be set to prevent access to the
programming settings of the brewer. Once all
the correct brew settings are programmed, the
operator can set the switch to the "ON" position to
prohibit anyone from changing the settings. With
the switch in the "ON" position, the programming
menus can still be accessed to view the current
settings. However, no changes will be saved.
The YES or NO should be flashing. Select YES
to prevent brewing if the water temperature is
below the set READY temperature. Select NO
to permit brewing at any water temperature.
When finished, press and release DONE. This
will step to the next function screen. To return
to the MAIN SCREEN at any time, press and
release "ENABLE BREW ON/OFF".
Disconnect brewer from
power source before
removing any panel!
P3634