Bunn FMD-2 Beverage Dispenser User Manual


 
26
SERVICE (cont.)
LIMIT THERMOSTAT
FIG. 20 LIMIT THERMOSTAT
P1445
Location:
The limit thermostat is located in the center of
the tank lid.
Test Procedures:
1. Disconnect the dispenser from the power source.
2. Disconnect both black wires from the limit ther-
mostat.
3. Check for continuity across the limit thermostat
terminals.
If continuity is present as described, the limit thermo-
stat is operating properly.
If continuity is not present as described, replace the
limit thermostat.
FIG. 21 LIMIT THERMOSTAT TERMINALS
P1800
Removal and Replacement:
1. Remove all wires from the limit thermostat ter-
minals.
2. Carefully slide the limit thermostat out from un-
der the retaining clip and remove the limit ther-
mostat.
3. Carefully slide the new limit thermostat into the
retaining clip.
4. Refer to Fig. 21 when reconnecting the wires.