13
ENTER PASSWORD
(-) 0 (+)
SET PASSWORD ?
(-) 0 (+)
2 OR 3 PRODUCTS?
(2) EXIT (3)
SELECT UNITS
ENG EXIT METRIC
REFRIGERATION ?
ON EXIT OFF
DEICE CYCLE TIME
(-) 120 MIN (+)
RINSE ALARM ?
NO EXIT YES
RINSE TIME ?
(-) 12 HRS (+)
RINSE LOCKOUT ?
NO EXIT YES
The following functions can be Password Protected. If you wish to prevent others from accessing these functions,
enter a 4 digit code of your choice. Record your password code [_ _ _ _], as you will need it to access these
functions in the future.
Use the (+) or (-) buttons to
enter password.
Use the (+) or (-) buttons to
change the password.
Select the number of products
to be dispensed
Select the preferred units.
Select OFF to disable the
Refrigeration system
Select the time delay between
automatic deicing of the
cabinet
Select (YES) or (NO)
Use the (+) or (-) buttons to
adjust Rinse Alarm delay.
Select (YES) to enable
Enter the access Code to view the remaining
functions. Factory Default = 0.
Enter your own Code to prevent access to the
remaining functions. [0 to 9999]
Used to switch from standard 3 products to 2
products w/Autoswitching of the Left and Middle
Bibs.
Used to select the preferred units of measurement.
(Oz., Gal, deg F) or (mL, L, deg C)
Select OFF to temporarily override a cooling system
fault and allow the machine to dispense coffee.
If ice builds up on the evaporator - decrease the
delay. If the cabinet is not cold enough - increase
the delay.
Factory Default=120 (2 hrs)[min=30, max=180]
Selecting Yes will enable the Rinse Alarm function,
(see Rinse Alarm)
Enter the desired time between required Rinse
Cycles in hours. [8 to 24 hrs]
Select YES to Lockout dispensing until the Rinse
Alarm has been cleared. Default is NO.
LCD DISPLAY ACTION DESCRIPTION
PROGRAMMING (Continued)
41129 071409
TANK TEMP 190
(-) EXIT (+)
READY TEMP 180
(-) EXIT (+)
CABINET TEMP 38
(-) EXIT (+)
Use the (+) or (-) buttons to
adjust the target Temp.
Use the (+) or (-) buttons to
adjust the target Temp.
Use the (+) or (-) buttons to
adjust the target Temp.
Sets the water Tank temperature:
(120 - 200°F) or (49 - 93°C)
Sets the hot water Ready temperature:
Typically set to the min. desired dispense temp.
Sets the Chilled cabinet target temperature:
(38 - 50°F) or (3 - 10°C)
LCD DISPLAY ACTION DESCRIPTION
If ON
If YES
If NO
to Next Page