Bunn LCR-3 Beverage Dispenser User Manual


 
16
LCD DISPLAY ACTION DESCRIPTION
PROGRAMMING (Continued)
XXOVERFLOW > 155
(-) EXIT (+)
XX REFILL -> 155
(-) EXIT (+)
WTR START DELAY
(-) .15SEC (+)
WTR STOP DELAY
(-) .15SEC (+)
TEST SWITCHES ?
UseSwitchToTest
TEST REFILL ?
EXIT YES
TEST HEATER ?
EXIT YES
ENTER ASSET #
(-) 000000 (+)
SERIAL #
LCR 0000000
VIEW FAULTS?
(-) EXIT (+)
LATEST FAULT
NO FAULTS
FACTORY DEFAULTS
NO YES
Use the (+) or (-) buttons to
adjust Overflow threshold
Use the (+) or (-) buttons to
adjust Refill threshold
Use the (+) or (-) buttons to
adjust delay time
Use the (+) or (-) buttons to
adjust delay time
NONE
Momentarily depress (YES)
Momentarily depress (YES)
Use the (+) or (-) buttons to
enter the ASSET NUMBER
NONE
Select (+) to view the Fault
Conditions
Use the (+) or (-) to scroll
through the Faults
Select (YES) or (NO)
Used to set the Conductance Threshold for the
Tank Overflow Probe
Used to set the Conductance Threshold for the
Tank Refill Probe.
Dispense Valve ON Delay. Eliminates weak mix
at the beginning of a dispense.
Dispense Valve OFF Delay. Flushes the mix
chamber at the end of a dispense.
Switch Diagnostic: Activate switches separately to
test. Display will indicate which Switch has been
activated. NOTE: Door Interlock switch must be
held closed.
Refill Valve Diagnostic: Press YES to momentarily
energize the Solenoid. CAUTION: Inlet Valve will
open and water will flow, if connected and turned
ON.
Tank Heater Diagnostic: Press YES to momentarily
energize the Tank Heater Circuit. CAUTION: AC
power will be applied to the Tank Heater Circuit.
Allows the user the option of entering an Asset
Number. Default is 000000
Displays the manufacture’s Serial Number (should
be identical to the Serial Number on the Data
Plate)
This unit stores the last 3 Fault Conditions in
memory for diagnostic purposes.
Displays up to 3 FAULT Conditions or NO
FAULTS, if nothing has failed since the last “Reset
Defaults”.
CAUTION: Selecting YES will RESET all Program-
ming Functions to the Factory Default settings
41129 021709