Bunn LCR-3 Beverage Dispenser User Manual


 
22
Check Pump & Flow Rate Calibration, refer
to Field Calibration Procedures
The calculated Target RPM for
the pump indicated is out of
range
____ TARGET RPM
TOO HIGH !!
Replace BIB, see Loading the Concentrate
Check BIB Connector Fittings
Check Tubing Installation
Check Empty BIB Threshhold, see Field
Calibrating the Epmty BIB Warning
Concentrate BIB is empty.
BIB not properly connected.
Tubing kinked or blocked.
Empty BIB Threshhold too high.
XXXX BIB EMPTY
Replace BIB Soon
Rinse Dispenser, see Rinse Procedure
Replace BIB, see Loading the Concentrate
Rinse Alarm Time Interval has
expired
RINSE REQUIRED
Wait for water temp to rise
Check Ready Temp. threshhold setting
Service Required
Water temp is below the preset
READY temp
HEATING
Please Wait!
Check Master ON/OFF Switch
Check Power Cord & Circuit Breaker
Service Required
No Power to the Dispenser
NO DISPLAY
Troubleshooting
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
Only qualified service personnel should perform inspection, testing, and repair of electrical equipment.
Shorting the terminals or the application of external voltages to electronic components may result in component
or circuit board failure.
Intermittent operation of electronic circuit boards is unlikely. board failure will normally be permanent. If an
intermittent condition is encountered, the cause will likely be a switch contact or a loose wire connection at
a terminal or crimp.
Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will
help avoid twists and kinks in the tubing.
Make certain that all plumbing connections are sealed and all electrical connections are tight and isolated.
This dispenser is heated at all times. Keep away from combustibles.
WARNING:
Exercise extreme caution when servicing electrical equipment.
Disconnect the brewer from the power source when servicing, except when electrical tests are specified.
Follow recommended service procedures.
Replace all protective shields or safety notices.
Screen Displayed Possible Cause Troubleshooting Procedures