ELECTRICAL REQUIREMENTS
CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up.
U333 & U3833 requires 3-wire, grounded service
rated 240 volt ac, 35 amp or 440 volts ac, 30 amp for
U333,three phase, 60 Hz or 380 volts ac, 30 amp for
U3833, three phase, 50 Hz. Proceed as follows:
U3 & U38 requires 3-wire, grounded service rated
120/208 or 120/240 volts ac, U3-30 amp,U38-40 amp,
single phase, 60 Hz. Proceed as follows:
ELECTRICAL INSTALLATION INSTRUCTIONS
NOTE: Electrical source should have a circuit breaker between the brewer and the main supply which breaks all
poles with a contact separation of at least 3 mm.
CAUTION – Improper electrical installation will damage electronic components.
1. An electrician must provide electrical service as specified.
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
3. Before electrically connecting the brewer, remove the front cupola cover (some models have the thermostat
knob on the outside of the cover) and rotate the thermostat knob fully counterclockwise to the "OFF" position.
Keep this knob in the "OFF" position until performing the Initial Setup.
4. Electrical service is connected at the upper rear of the single service and scrambler brewers using a junc-
tion box. On double service brewers the rear decorative channel must be removed for access to the terminal
block.
5. Connect the brewer to the power source and verify the voltage at the terminal block before proceeding. Re-
place all panels.
6. If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing
has been hooked up, the brewer is ready for Initial Setup.
NOTE: Schematic wiring diagrams are included in this manual.
GREEN GREEN
U3A models require 2-wire, grounded service rated
230 volts ac, 30 amp, single phase, 50 Hz. Proceed
as follows:
U3833 requires 4-wire, grounded service rated
380 volts ac or 440 volts ac, 30 amp, three phase, 50
Hz. Proceed as follows:
230V A.C.
RED
BLACK
GREEN GREEN
L1, L2, L3, are the 3 phases
V1 = Phase to phase voltage,
between any 2 phases.
V2 = Phase to neutral voltage,
any phase to neutral.
SYSTEM
VOLTAGE V1 V2
208 208 120
240 240 139
380 380 220
440 440 254
P1842
P1844
10060 011708
GREEN GREEN
L2 RED
WHITE
NEUTRAL
L1 BLACK
120V A.C.
208 OR
240V A.C.
RED
BLACK
BLUE
120V A.C.
208V OR 240V
380V OR 440V
208V OR 240V
380V OR 440V
208V OR 240V
380V OR 440V
P1841
P1843
L2
L3
L1
L1
L2
RED
BLACK
L1
L2
L3
N
WHITE
BLUE
(NEUTRAL)