Bunn VLPF Coffeemaker User Manual


 
Page 8
TROUBLESHOOTING (cont.)
PROBLEM
Equipment will not operate
Brew cycle will not start
Automatic refill will not operate af-
ter drawing hot water.
PROBABLE CAUSE
1. No power or incorrect voltage
1. No water
2. Water strainer/Flow Control
3. On/Left switch
4. Start switch
5. Brew timer
6. Relay
7. Solenoid valve
1. On/Left switch
REMEDY
(A) Plug in brewer.
(B) Check wall outlet for 120V ac
(C) Check circuit breaker/fuse.
Check plumbing and shut-off
valves.
(A) Direction of flow arrow must
be pointing towards brewer.
(B) Remove the strainer/Flow con-
trol and check for obstructions.
Clear or replace.
Refer to
Service -
On/Left switch
for testing procedures. See page
22.
Refer to
Service -
Start switch for
testing procedures. See page 26.
Refer to
Service -
Brew timer for
testing procedures. See page 16.
Refer to
Service -
Relay for test-
ing procedures. See page 23.
Refer to
Service -
Solenoid valve
for testing procedures. See page
25.
(A) The On/Left switch must be in
the upper position for the auto-
matic refill to operate.
(B) Refer to
Service -
On/Left
switch for testing procedures. See
page 22.
10179 060100