Cabletron Systems 1800 Water Dispenser User Manual


 
Trap Messages 3-21
Configuring the Trap Table
BSCI: Invalid queue operations 521
An invalid operation has occurred and has disabled the port.
Severity Minor (Level 3)
Action Take the same action as for message 500.
BSCI: Invalid protocol operations 522
An invalid operation has occurred and has disabled the port.
Severity Minor (Level 3)
Action Take the same action as for message 500.
BSCI: Invalid CUA, DUA operations 523
An invalid operation has occurred and has disabled the port.
Severity Minor (Level 3)
Action Take the same action as for message 500.
Invalid Line Speed LP “n” Port “n” 524
Self-explanatory.
Severity Minor (Level 3)
Action Correct the line speed in the Port record.
I-FRM Blocked-Remote Busy Timeout 530
An RNR (Receive Not Ready) condition on the port has been cleared by
expiration of the Remote Busy Timer, which caused the port to be reset.
Severity Major (Level 2)
Action Check the user device for a problem that caused the RNR.
I-FRM Blocked-No Acks from Remote 531
The remote user device is not accepting transmission from the local device, and
the local port has been reset.
Severity Major (Level 2)
Action Check the remote device for a problem.
Enter Service Affecting Condition 532
The DTE and DCE exchange messages regularly so that each knows the other is
running and ready. If one end does not respond, this event message is sent and
the link goes down.
Severity Major (Level 2)
Action Check the equipment to see what caused the failure to respond.