Configuring the Trap Table
3-6 Trap Messages
LP Trn Frm/Sec exceeded T: “n” C: “n” 307
The RLP statistic Transmitted Frames/Sec has exceeded the threshold (T: ÒnÓ)
that was set by the user. (C: ÒnÓ is the current value.)
Severity Informational (Level 4)
Action If this happens frequently, you may need to reroute some trafÞc.
LP Rej Frm/Sec exceeded T: “n” C: “n” 308
The RLP statistic Rejected Frames/Sec has exceeded the threshold (T: ÒnÓ) that
was set by the user. (C: ÒnÓ is the current value.)
Severity Informational (Level 4)
Action If this happens frequently, check the line for noise and check for
conÞguration errors on both the FRX port and the connected user
device.
LP Rtrn Frm/S exceeded T: “n” C: “n” 309
The RLP statistic Retransmitted Frames/Sec has exceeded the threshold (T: ÒnÓ)
that was set by the user. (C: ÒnÓ is the current value.)
Severity Informational (Level 4)
Action If this happens frequently, check the line for noise and check for
conÞguration errors on both the FRX port and the connected user
device.
Rcv Frm/Sec exceeded T: “n” C: “n” 311
The port statistic Received Frames/Sec has exceeded the threshold (T: ÒnÓ) that
was set by the user. (C: ÒnÓ is the current value.)
Severity Informational (Level 4)
Action If this happens frequently, you may need to reroute some trafÞc.
Tran Frm/Sec exceeded T: “n” C: “n” 312
The port statistic Transmitted Frames/Sec has exceeded the threshold (T: ÒnÓ)
that was set by the user. (C: ÒnÓ is the current value.)
Severity Informational (Level 4)
Action If this happens frequently, you may need to reroute some trafÞc.
RTrn Frm/Sec exceeded T: “n” C: “n” 313
The port statistic Retran Frames/Sec has exceeded the threshold (T: ÒnÓ) that was
set by the user. (C: ÒnÓ is the current value.)
Severity Informational (Level 4)
Action If this happens frequently, check the line for noise, and check for
conÞguration errors on both the FRX port and the connected user
device.