Carrier 30XW325-400 Water Dispenser User Manual


 
5
Model number nomenclature
a30-4744
30XW – 325 6 – 4 3 B
30XW – AquaForce
®
Water-Cooled
Screw Chiller
Design Series
Unit Size (Nominal Tons) (kW)
325325 (1133)
350350 (1206)
400 – 400 (1354)
Voltage
1 – 575-3-60
2380-3-60
4 – 230-3-60
6 – 460-3-60
7 – 200-3-60
Condenser Options
- – 2 Pass, NIH, 150 psig (1034 kPa), Victaulic, Discharge Connections (Std)
0 – 2 Pass, NIH, 150 psig (1034 kPa), Victaulic, Suction Connections
1 – 2 Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Connections
2 – 2 Pass, NIH, 150 psig (1034 kPa), Flange, Suction Connections
3 – 2 Pass, NIH, 300 psig (2068 kPa), Victaulic, Discharge Connections
4 – 2 Pass, NIH, 300 psig (2068 kPa), Victaulic, Suction Connections
5 – 2 Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Connections
6 – 2 Pass, NIH, 300 psig (2068 kPa), Flange,
Suction Connections
7 – 2 Pass, MWB, 150 psig (1034 kPa), Victaulic, Discharge Connections
8 – 2 Pass, MWB, 150 psig (1034 kPa), Victaulic, Suction Connections
9 – 2 Pass, MWB, 300 psig (2068 kPa), Victaulic, Discharge Connections
B – 2 Pass, MWB, 300 psig (2068 kPa), Victaulic, Suction Connections
C – 2 Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Connections
D – 2 Pass, MWB, 150 psig (1034 kPa), Flange, Su
ction Connections
F – 2 Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Connections
G – 2 Pass, MWB, 300 psig (2068 kPa), Flange, Suction Connections
H – 1 Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Leaving
J – 1 Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Leaving
K – 1 Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Leaving
L – 1 Pass, MWB, 300 ps
ig (2068 kPa), Flange, Discharge Leaving
Heat Machine
-Std Condenser/Comfort Cooling (Std)
M – Heat Machine Condenser/Comfort Cooling
Evaporator Options
- – 2 Pass, NIH, 150 psig (1034 kPa), Victaulic, Discharge Connections (Std)
0 – 2 Pass, NIH, 150 psig (1034 kPa), Victaulic, Suction Connections
1 – 2 Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Connections
2 – 2 Pass, NIH, 150 psig (1034 kPa), Flange, Suction Connections
3
– 2 Pass, NIH, 300 psig (2068 kPa), Victaulic, Discharge Connections
4 – 2 Pass, NIH, 300 psig (2068 kPa), Victaulic, Suction Connections
5 – 2 Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Connections
6 – 2 Pass, NIH, 300 psig (2068 kPa), Flange, Suction Connections
7 – 2 Pass, MWB, 150 psig (1034 kPa), Victaulic, Discharge Connections
8 – 2 Pass, MWB, 150 psig (1034 kPa), Victaulic, Su
ction Connections
9 – 2 Pass, MWB, 300 psig (2068 kPa), Victaulic, Discharge Connections
B 2 Pass, MWB, 300 psig (2068 kPa), Victaulic, Suction Connections
C 2 Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Connections
D 2 Pass, MWB, 150 psig (1034 kPa), Flange, Suction Connections
F 2 Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Connections
G – 2 Pass, MWB, 300 psig (2068 kPa), Fl
ange, Suction Connections
H
– 1 Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Leaving
J – 1 Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Leaving
K 1 Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Leaving
L 1 Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Leaving
M 3 Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Leaving
N 3 Pass, NIH, 150 psig (1034 kPa), Flange, Suction Leaving
P 3 Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Leaving
Q 3 Pass, NIH, 300 psig (2068 kPa), Flange, Suction Leaving
R 3 Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Leaving
S 3 Pass, MWB, 150 psig (1034 kPa), Flange, Suction Leaving
T 3
Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Leaving
V 3 Pass, MWB, 300 psig (2068 kPa), Flange, Suction Leaving
Packaging/Charging Options
B R-134a Refrigerant with Bag (Std)
C R-134a Refrigerant with Crate Over Bag
D Nitrogen Refrigerant with Bag
F Nitrogen Refrigerant with Crate Over Bag
Controls/Communications Options
- – Navigator™ Displa
y
0 – Navigator Display, EMM
1 – Navigator Display, GFCI Service Option
2 – Navigator Display, EMM, GFCI Service Option
3 – Touch Pilot™ Display (Std)
4 – Touch Pilot, EMM
5 – Touch Pilot, GFCI Service Option
6 – Touch Pilot, EMM, GFCI Service Option
7 – Navigator Display, BACnet™ Translator
8 – Navigator Display, EMM, BACnet Translator
9 – Navigator Displ
ay, GFCI Service Option,
BACnet Translator
B Navigator Display, EMM, GFCI Service Option,
BACnet Translator
C Touch Pilot Display (Std), BACnet Translator
D Touch Pilot Display, EMM, BACnet Translator
F Touch Pilot Display, GFCI Service Option,
BACnet Translator
G – Touch Pilot Display, EMM, GFCI Service Option,
BACnet Translator
H Navigator Dis
play, LON Translator
J – Navigator Display, EMM, LON Translator
K Navigator Display, GFCI Service Option,
LON Translator
L Navigator Display, EMM, GFCI Service Option,
LON Translator
M – Touch Pilot Display (Std), LON Translator
N Touch Pilot Display, EMM, LON Translator
P Touch Pilot Display, GFCI
Service Option,
LON Translator
Q – Touch Pilot Display, EMM, GFCI Service
Option, LON Translator
Electrical Options
- Single Point, XL S ta rter, Terminal Block
(Std 380, 460, 575-v)
0 Single Point, Wye-Delta Starter, Terminal
Block (Std 200,230-v)
3 – Dual Point, XL Starter, Terminal Block
4 – Dual Point, Wye-Delta Starter, Terminal Block
7 Single Point, XL Starter, Non-Fused Disconnect
8 Single Point, Wye-Delta, Non-Fus
ed Disconnect
C Dual Point, XL Starter, Non-Fused Disconnect
D Dual Point, Wye-Delta Starter, Non-Fused
Disconnect
H Single Point, XL Starter, Terminal Block, CPT
J Single Point, Wye-Delta Starter, Terminal
Block, CPT
M – Dual Point, XL Starter, Terminal Block, CPT
N Dual Point, Wye-Delta Starter, Terminal
Block, CPT
R Single Point, XL Starter, Non-Fused
Disconnect, CPT
S Single Point, Wye-Delta, Non-Fused
Disconnect, CPT
W
– Dual Point, XL Starter, Non-Fused
Disconnect, CPT
X Dual Point, Wye-Delta Starter, Non-Fused
Disconnect, CPT
Refrigeration Circuit Options
*
4 Standard Unit
6 – With Suction Service Valves
D With Minimum Load Control
G – With Suction Service Valves and Minimum
Load Control
N With Condenser Insulation for Heat Machine
Q – With Suction Service Valves and Condenser
Insulation for Heat Machine
X With Minimum Load Control and Condenser
Insulation for Heat Machine
Z With Suction Service Va
lves, Minimum Load
Control and Condenser Insulation for
Heat Machine
LEGEND
*Evaporator insulation is standard.
Quality Assurance
Certified to ISO 9001:2000
CPT Control Power Transformer MWB Marine Waterbox
EMM Energy Management Module NIH Nozzle-In-Head
GFCI Ground Fault Circuit Interrupter XL Across-the-Line Start
LON Local Operating Network