CDA SC309 Oven User Manual


 
The oven is designed to fit into a cabinet of 600 mm width.
The oven can be built in or built under the kitchen units, but you must ensure that it is
properly ventilated.
In the diagram the built in oven is ventilated by means of a space at the top of the
kitchen cabinet. There are many other methods of ventilating your oven.
Consult a qualified engineer for advice.
IMPORTANT: If the oven is being installed into a built under oven housing unit ensure
that the front rail at the top of the unit is not installed as it will restrict ventilation.
Ventilation
The appliance may be installed in a kitchen, Kitchen/diner or a bed sitting room, but not in a
room or space containing a bath or a shower.
3
The appliance must not be installed in a bed-sitting room of less than 20 m .
The appliance is designed and approved for domestic use only and should not be installed in
a commercial, semi commercial or communal environment.
Your product will not be guaranteed if installed in any of the above environments and could
affect any third party or public liability insurances you may have.
The appliance should be installed into a room or space with an air supply in accordance with
BS 5440-2: 2000.
3 2
For rooms with a volume of less than 5 m - permanent ventilation of 100 cm free area will be
required.
3 3 2
For rooms with a volume of between 5 m and 10 m a permanent ventilation of 50 cm free
area will be required unless the room has a door which opens directly to the outside air in
which case no permanent ventilation is required.
3
For rooms with a volume greater than 10 m - no permanent ventilation is required.
NB. Regardless of room size, all rooms containing the appliance must have direct
access to the outside air via an openable window or equivalent.
Where there are other fuel burning appliances in the same room, BS 5440-2: 2000 should be
consulted to determine the correct amount of free area ventilation requirements.
The above requirements allow also for use of a gas oven and grill but if there are other gas
burning appliances in the same room, consult a qualified engineer.
Location
8