Cleveland Range 22CGT6 Oven User Manual


 
10
SteamChe
f
MAIN EXTERNAL
POWER SWITCH
The fuse or breaker and disconnect switch combination is called the “Main External Power Switch.”
See Figure 3-7.
This appliance is not suitable for connection to a power cord. Do NOT use a power cord.
This appliance is not suitable for connection to a GFCI (GFI). Do NOT use a GFCI (GFI).
4. Remove the control side panel.
5. Make the electrical connection using sufficient length of flexible conduit, per local code, so the
SteamChef can be moved for service.
6. Mechanically secure the flexible conduit to the SteamChef’s electrical access hole.
7. Check all cable and wire connections for size, location, and tightness.
8. Replace the control side panel and secure it to the SteamChef before starting the SteamChef.
Figure 3-7
Main External Power Switch
H. Install the Free Air Vented Drain Line
NOTICE: Furnishing and installing drain lines and drainpipe is the responsibility of the Owner/Installer.
NOTICE: Improper installation of drain outlet lines voids the SteamChef Warranty.
The following restrictions and requirements are critical to the safety of personnel and equipment,
and must not be violated under any circumstances:
1. The drain lines must be installed in compliance with the Food Code (latest edition) of the Food and
Drug Administration (FDA), and any other applicable national, state, or local codes and regulations.
2. The drain line must be free air vented, have gravity flow from the SteamChef, and terminate outside
the perimeter of the SteamChef.
3. Free air venting requires a minimum 1” clearance between the end of the drain line and the top of
the floor drain. See Figure 3-8.
4. Do NOT install the SteamChef directly over a drain. Steam rising up out of the drain will adversely
affect operation, hamper cooling air circulation, and damage electrical and electronic components.
5. Do NOT connect the SteamChef drain connection to any drain material that cannot sustain 180
o
F.
6. Do NOT connect drains from any other equipment to the drain line of the SteamChef.
7. Do NOT connect the drain outlet extension line directly into a floor drain or a sewer line.
DEATH, INJURY, EQUIPMENT and PROPERTY DAMAGE
will result from improper installation of drain outlet lines.
Install free air vented drain lines as described in this manual.