Conair GB Blender User Manual


 
One Conair Drive Pittsburgh, PA 15202 412-312-6000 FAX 412-312-6227 www.conairnet.com
MODELS GB920 GB940 GB960
Performance characteristics
Batch size lbs {g} 19.8 {9000} 19.8 {9000} 19.8 {9000}
Maximum throughput lbs/hr {kg/hr}* 5200 {2359} 3300 {1497} 2124 {965}
Bin capacity - main ingredient ft
3
{liter} 8.5 {240.7} 6.7 {189.7} 3.6 {102.9}
Bin capacity - minor ingredient ft
3
{liter} NA 3.6 {107.6} 3.6 {107.6}
Maximum number of materials 6 8 10
Number of discharge valves 2 4 6
Number of additive feeders up to 4 up to 4 up to 4
Control software (# of components) 4 or 12 4 or 12 12
Dimensions inches {mm}
A - Height above mounting plate
74 {1880.7} 74 {1880.7} 74 {1880.7}
B - Width
56 {1421.4} 56 {1421.4} 56 {1421.4}
C - Depth
34 {863.6} 34 {863.6} 34 {863.6}
D - Controller height 11.25 {285.75} 11.25 {285.75} 11.25 {285.75}
E - Controller width 12.25 {311.15} 12.25 {311.15} 12.25 {311.15}
F - Controller depth 8.19 {208.03} 8.19 {208.03} 8.19 {208.03}
Weight lbs {kg}
Installed 480 {218} 480 {218} 480 {218}
Shipping 600 {272.2} 600 {272.2} 600 {272.2}
Voltage Running load amps
§
120V/1 phase/60 hz (control and mixer) 8.5 8.5 8.5
220V/1 phase/60 hz (control and mixer) 4.25 4.25 4.25
220V/1 phase/50 hz (control) 0.15 0.15 0.15
220V/3 phase/50 hz (mixer) 2.2 2.2 2.2
400V/3 phase/50 hz (mixer) 1.1 1.1 1.1
Compressed air requirements
Discharge valves 80 psi @ 0.2 ft
3
/min {5.5 bars @ 0.09 liters/sec}; 1/4 in. NPT fitting
Compressed air feeder 40 psi @ 2.0 ft
3
/min {2.8 bars @ 0.94 liters/sec}; 1/4 in. NPT fitting
Maximum loader sizes **
Number of 20 inch loaders 2 2 3
Number of 15 inch loaders 2 4 6
GRAVIMETRIC BATCH BLENDERS
AutoWeigh GB900 Series Models
MOUNTING INTERFACE
SPECIFICATION NOTES:
* Maximum throughput rates are based on 35 lbft
3
pelletized material and using all dispense valves.
Use of feeders for minor ingredients will reduce
this rate. Refer to the selection guide for more
specific throughput information.
The optional flow control valve will add 6.5 in. {165
mm} to the total height.We recommend using the
flow control valve when mounting the blender to a
stand, surge bin or hopper.
Feeders will increase depth dimensions. Please
refer to feeder specification.
§
Each auger feeder requires an additional 1 amp @
120V or 0.5 amp @ 240V.
** Maximum loader sizes may be used only when the
loader is adjacent to loaders of a smaller diameter.
SPECIFICATIONS
TPBS013/1199
IBO4
CONTROL
FEEDER LOCATIONS
2
1
D
C
B
A
B
C
GB920
2
1
D
C
B
A
B
C
GB940
A
B
C
GB960
4
3
8
1
7
2
4
3
A
B
C
FRONT VIEW
GB920
SIDE VIEW
GB920/GB940
A
B
C
FRONT VIEW
GB940/GB960
SIDE VIEW
GB960
B
C
D
NOTE: Any one of the
feeders (A,B,C or D)can be
designated position 5 or 6.