Country Flame LR-01 Range User Manual


 
Version 1.0 Page 23
6. The LR-01 is designed to accept installations using a horizontal vent through an exterior wall.
A horizontal flue pipe installation should be a minimum of 24” from pellet stove vent pipe to
flue cap connection. FIGURE 1 shows a through the wall exterior vent installation.
WALL THIMBLE
EXTERIOR WALL
FLUE PIPE
JET CAP
FLUE PIPE
CLEAN OUT "T"
EXTERIOR WALL
JET CAP
FIGURE 1: HORIZONTAL VENT PIPE (2 options)
7. FIGURE 2 shows a traditional, as well as more efficient, flue pipe installation. Note the
dimensions that are required to be maintained in this type of installation. Dimensions are A
equals a minimum of 24”, B equals a minimum of 3”, and C equals a minimum of 6”. Again,
check with the flue pipe manufacturer’s installation instructions and code requirements for
exact specifications. DIMENSIONS:
FIGURE 2: TRADITIONAL VENT PIPE