Country Flame LR-01 Range User Manual


 
Version 1.0 7
SPECIFICATIONS
FUEL TYPE: A.P.F.I. residential fuel:
Heat Content: 8200 BTU/lb. min.
Bulk Density: 40 lb. /cubic ft. min.
Moisture Content: 8% max
Ash Content: 1% max
Size: ¼” to 3/8” diameter
1.5” long max
Fines: 1% max through 1/8
th
screen
HOPPER SIZE: 55# Hopper Capacity
FLUE SIZE: 3” or 4”
TYPE: PL double wall vent with stainless steel inner liner
AIR INLET: 1 ½” Sch 40 Black Iron Pipe
AUGER TYPE: Tumac 2 ¼ Auger Pellet Feed System
CONTROLS: Integrated Feed Rate/Blower Speed Controls
ELECTRICAL: 120 Volts, 2.4 Amp, 60 Hz
MEASUREMENTS: UNIT BODY HEIGHT 22 ¾”
HEIGHT ON PEDESTAL 32 ¾”
HEIGHT ON LEGS 31 1/4”
UNIT WIDTH 26”
UNIT DEPTH 19 3/4”
SHROUD HEIGHT 29 7/8”
SHROUD WIDTH 45 7/8”
CLEARANCES: SIDES 1”
BACK 2
TOP TO COMBUSTIBLE 3”
TOP TO CEILING 3
*Combustible Flooring must be covered with non-combustible material extending 6”
(150 mm) from front of unit and 8” (205 mm) from unit on each side. The floor
protection on the sides of the stove only has to extend to the vertical sidewall(s) if the
clearances are less than 8”.