DeLonghi EUROCHEF - PRO Ventilation Hood User Manual


 
11
Air-2
EUROCHEF - PRO WALL HOOD
STEP 3B: ALTERNATE MOUNTING
METHOD
INSTALL HOOD TO SOFFIT OR BENEATH CABINETS
SKIP THIS STEP IF USING WALL MOUNTING METHOD
When necessary, the hood may be installed so that it is
supported by the soffit.
The soffit should be constructed with 2 x 4’s.
Determine the installation location on the wall.
Continue the centerline forward on the bottom of the cabinet
or soffit.
If ducting vertically the opening above the hood should allow
for the 8" round duct and clearance to slide the hood back
against the wall. Requires 8" Min. Opening For Ductwork
and Hood Installation
The 2 x 4 studs must be located as shown in the chart, Dim.
A. to accept mounting screws.
IMPORTANT: For additional support and to minimize
vibration during operation, the hood must be secured
to the back wall. Use wall anchors to fasten bottom
back of hood to the wall.
Drive mounting screws into the studs until they protrude
1/4". The 1/4" gap will provide clearance to engage the key-
hole slots in the top of the hood.
Lift hood to installation position. Locate house wiring and
route through the knockout (from the back or top of the hood).
Lift hood onto mounting screws. Slide back against the rear
wall.
Tighten mounting screws.
Add (2) security screws in top left and top right side of hood.
Requires 8” Min. Opening
For Ductwork and Hood
Installation
“A”
Centerline to Stud
and Keyhole Slots
PRO HOOD 24” 11 - 9/16”
PRO HOOD 30” 14 - 9/16”
PRO HOOD 36” 17 - 9/16”
PRO HOOD 48” 23 - 9/16”
Drill 1/8" pilot holes into the studs at the locations shown in
the top view illustration.
Top of hood
Mount Hood onto Soffit or Cabinet
Note: If mounting to the underside of a cabinet with a recessed
bottom, install shims to fill the gap.
9” 3/4
A
C
L
3”
½
Affix enclosed paper template to wall
IMPORTANT: FRAMING MUST BE CAPABLE OF
SUPPORTING UP TO 150 LBS