Electrolux 736684 Refrigerator User Manual


 
24
buzzer: buzzer activated
WHAT IS RECORDED?
Press
HACCP
the buzzer goes off; press again for 5
seconds until the alarm (AL1) is displayed.
Press again
HACCP
the temperature, start date and
time are given in a message: “TEMP 78.8F/26C Start 17.05
10-10-99 End——”.
b) The alarm has already occurred
41˚/5˚
5
0˚/10˚
5
9˚/15˚
6
8˚/20˚
7
7˚/25˚
Temperature ˚F/˚C
Critical temperature
Critical temperature
17:00
18:00
16:00
19:00
20:00 21:00
22:0
0
tim
e
CHECKING
display: the message “TEMP” is displayed
buzzer: buzzer activated
WHAT IS RECORDED?
Press
HACCP
the buzzer goes off; press again for 5
seconds until the alarm (AL1) is displayed.
Press again
HACCP
the temperature, start date and time
are given in a message: “TEMP 78.8F/26C Start 17.05 10-10-
99 End——”.
To access the recorded HACCP alarms press the
button
HACCP
for 4 seconds; the display will now show
HISt and then AL_1 (alarm symbol); this shows the last alarm
for the max. compartment temperature stored in the PCB. Press
the button
HACCP
to display the value of the last alarm
for max. compartment temperature. The display now shows:
- TEMP 78.8F/26C (type and value of the alarm for max.
compartment temperature)
- Start date and time (alarm activation date and time)
- End date and time (alarm end date and time)
Press the button
HACCP
to display the alarm (AL1)
symbol again. Press the button
HACCP
to display the
next alarm for max. compartment temperature. If no button is
pressed within 10 seconds the HACCP section is quitted.
· CHECKING OLD ALARMS
Hold down the button
HACCP
:: the display shows AL1
(last alarm); to select the other alarms (AL2, AL3,...) press
.
· FOR HOW LONG ARE THE ALARMS STORED?
Permanently, at least while there is space in the memory (max.
number of alarms recorded: 99).
C.1.7.3 SERVICE ALARMS
To access the SERVICE ALARMS press the
button for 4 seconds; the display shows the first
SERVICE ALARM stored in the electronic panel, e.g. “b1” (door
open). Press the button
to display the next
SERVICE ALARM stored in the electronic panel. If other SERVICE
ALARMS are not stored in the electronic panel, the display shows
“——”. If no button is pressed within 5 seconds, the SERVICE
ALARMS section is quitted.
· FOR HOW LONG ARE THE ALARMS STORED?
Until the entire list of stored alarms is displayed. After which
they will remain stored until another alarm occurs: resetting is
automatic.
· ALARM SIGNALING
- alarm button LED flashing
- buzzer activated (acoustic alarm)
· CHECKING ALARMS
Hold down the button
the display shows the last
alarm that occurred (a message) and the buzzer is deactivated.
To reset the alarm, press
until “——” is
displayed.