32
If the units are intended to be fitted
adjacent to the appliance but less
than 400mm above the hotplate,
then a minimum space of 100mm
must be maintained between the
sides of the unit and the appliance
(See Fig 1b). Curtains must not be
fitted immediately behind the
appliance or within 150mm of the
sides of the hotplate. If fitted next to
or between two base units a
minimum space of 1mm must be left
between each unit and the sides of
the appliance. The hotplate must be
set to a minimum of 7mm above the
adjacent units. (Note: The levelling
feet fitted to the appliance will
achieve a nominal height of 907mm
-5+ 13mm. Base units not meeting
the above conditions must be a
minimum of 100mm away from the
hotplate.
For appliances installed in the
Republic of Ireland please refer to
NSAI-Domestic Gas Installation
IS813 Current Edition Section7
Permitted Locations of appliance
Table4---Locations and Permanent
Ventilation requirements-flueless
appliances.
Note: - L.P.G. cookers MUST NOT
be installed below ground level i.e. in
a basement or aboard any boat,
yacht or other vessel.
Levelling the appliance
Adjustment to suit floor conditions or
height is obtained by rotating
clockwise or anti clockwise the feet
at the front and rear of the
appliance. A spirit level should be
placed on one of the shelves to
confirm the appliance is correctly
levelled.