The STATUS LED provides optical indication of CAN-bus trafc. When the
power amplier’s address is set to “00” so that it is separated from the CAN-
bus, the STATUS LED blinks every 3 seconds. When the power amplier’s
address is set between “01” and “250” and no CAN-bus activity has taken place yet, the LED blinks
every second. As soon as CAN-bus communication is recognized, the LED is activated for at least
100ms whenever the power amplier actively sends data on the CAN-bus.The STATUS LED may also
be activated from the PC. In this case, the LED of the according power amplier blinks fast and steady
while all other status-LEDs within the system stay dimmed. This function is useful for optically monitor-
ing communication and for quickly identifying particular power ampliers in extensive system installa-
tions (please also refer to the IRIS software documentation).
EASY REMOTE
Easy Remote provides a simple way to remotely power-on/off the power
amplier. The Easy Remote function is only useful for appliances not
employing a RCM-24 Module. Controlling appliances with RCM-24 Module
installed per Easy Remote is practically pointless.
EASY REMOTE IN
Leaving the pins of the EASY REMOTE IN socket open, i.e. when connecting +5V, the appliance
power is switched on. When connecting the EASY REMOTE IN, i.e. when feeding 0V from the control
output, the appliance enters standby mode.
EASY REMOTE SLAVE
The EASY REMOTE SLAVE connector provides connection for additional appliances with Easy-
Remote function (e.g. for switching several devices within a rack-shelf ON/OFF).
The switching of the slave-units is delayed to prevent the mains fuses from blowing.
POWER AMPLIFIER OUTPUTS
SPEAKON-type connectors are provided for the power amplier channels
„A“ and „B“. The BRIDGED OUT connector for bridged operation has a
plastic coverlid preventing inadvertent misconnection.
When connecting loudspeaker systems, please mind the polarity
according to the following diagram:
GROUND-LIFT SWITCH
The ground-lift switch allows eliminating noise loops. If the power amplier is
operated together with other equipment in a 19“ rack-shelf, setting the switch
to its GROUNDED position is recommended. If the power amplier is
operated together with appliances with differing ground potentials, setting
the switch to its UNGROUNDED position is recommended.