Emerson IP258 Oven User Manual


 
IP258
7
20
61
102
30
30
22
Standard gap = 150mm
Specify gap
50 to 450mm
2.2 MOBREY PIPE SECTION SENSORS
The Mobrey pipe section is used as part of a pipeline transporting the slurry to be monitored. Each pipe section
contains two sensors, installed with their faces accurately aligned and flush with the pipe inner wall, to avoid any
excessive slurry or grease build up on the faces.
Figure 4 : MSM448 Pipe Section Sensors
455
'O' ring
Sealing
face
Location pin
Retaining nut
R¾" (BS21:1973)
¾" BSPT
Material : 316 Stainless steel
Gap size : 100mm, 150mm, 200mm,
300mm, 450mm
(others on request)
Cable : Dual twin-axial
Max. Pressure : 105 kg/cm2 (103 bar)
Temperature range : -40°C to + 70°C (others on
request) Refer to Sensor
safety data for intrinsically
safe systems
Malleable cast iron epoxy coated
316 stainless steel
1" NPT
In line installation
DN100, DN150, DN200 to BS4772
(others on request)
10 Bar (PN10)
-40°C to +70°C(for T6), +120°(for T5)
(Others on request)
Refer to Sensor safety data for intrinsically
safe systems
Oil hose protected on pipe section,
Screened twisted pair
7m dual twin-axial from junction box (others
on request)
IP65 aluminium alloy
Material pipe section :
Material sensors :
Drain fitting :
Mounting connection :
Flanges :
Max pressure :
Temperature range :
Sensor cable :
Cable length :
Cable junction box :
2.0 SENSOR TYPES
2.1 SUSPENDED SENSOR TYPE MSM433
Figure 3 : MSM433 Sensor and Specifications