Fisher & Paykel DD605 Dishwasher User Manual


 
599464
30
U2 Restricted Lid Travel
Restricted lid travel. The lid has reached its stall current too soon.
The product will retry the lid 3 times, log the fault if the retries fail, then report
to the user.
PRIMARY ACTION
- Check dishes, cutlery or cups are not projecting above the top of the tub.
SECONDARY ACTION
- Check the lid actuator connections and operation in diagnostics.
- Check the yokes for jamming at the front and rear.
U3 Filled Too Quickly Or Failed To Drain
This fault is not displayed to the customer, but it is recorded in the fault history
and can be seen by Smart Tool.
If the motor senses prime too soon (in less than 20 seconds), it will drain and
refill up to 5 times, then continue the wash program regardless, and log the
fault.
PRIMARY ACTION
Not draining completely from previous fill, test in diagnostics.
Check for:
- A blocked drain or kinked drain hoses.
- Blocked drain sump inlet / outlet pipes.
- Blocked drain filter.
- Faulty rotor.
- Faulty connection to the motor.
- Faulty hall sensor.
SECONDARY ACTION
Filling too quickly. Check for:
- Excess water pressure.
- Faulty water inlet valve.