3 DIAGNOSTICS
3.1 DishDrawer™ Diagnostics
Dishwasher Diagnostics can only be entered in Power Off mode, i.e. when
there is no display on the LCD or the badge LED’s are off. Diagnostics is
entered by holding the KEYLOCK and START/PAUSE buttons
simultaneously for 5 seconds. Ensure that KEYLOCK is pressed first.
There are currently four levels of diagnostics. To move to the next level,
press POWER. To enter a level, press START/PAUSE. Once a level has
been entered, pressing POWER will exit diagnostics completely. If no level is
entered, then the display will cycle through the four levels and exit after the
last. On entering diagnostic mode, the first level is the Display/Download
Mode.
3.2
Display/Download Mode
In this mode, all LED’s and LCD segments (except keylock) are illuminated.
3.3
Optical LED Download/Fault Display
An optical data download is available here to download all EE data to a PC or
Palm PC via the lower tub-home sensor light pipe. Hold the reader pen over
the lower tub-home sensor light pipe and press START/PAUSE to initiate the
download. A short beep indicates the start and finish of download.
The last two faults are displayed on the LCD (secondary control panel LEDs
for integrated and flat door models) during the optical download. The Current
Fault code is displayed first followed by the Previous Fault Code. To read the
Fault Code on the secondary display, refer to Section
4.7 on Fault Codes.
3.4
Clearing Fault Logs
To clear the current fault code, press the KEYLOCK button until a beep is
sounded. This action moves the current fault into the previous fault while
clearing the current fault. To clear the previous fault code, press KEYLOCK
once more until the beep is sounded.
Warning: Once a fault code has been cleared, it is permanently removed
from memory and cannot be recovered.
Press POWER to advance to the next level.