Frymaster 35 Fryer User Manual


 
2-36
ITEM PART # COMPONENT
1 230-1178 Deector (Target) without Stiffener, Individual
2 230-1180 Deector (Target) Rear, Individual
807-1707 Ignitor, Natural
807-1708 Ignitor, Propane
3 826-1155 Ignitor Kit, Optional Piezo
4 810-1862
FV, Burner Manifold (full assembly including targets, 106-4205SP)
5
Orices (for high altitude and special gasses contact Frymaster)
826-1353 1.7 mm, Natural Gas (pkg. of 10)
826-1354 1.05 mm, Propane/Butane Gas (pkg. of 10)
810-0407 2.15 mm, Manufactured Gas
812-1203 1.00 mm, MJ Orice
6
Pilot Assemblies, Non-CE
810-1830 Natural Gas with Thermopile (Twin Push-on Terminals)
106-1908SP Natural Gas with Thermopile (Twin Spade Terminals)
106-1909SP Pro./But. Gas with Thermopile (Twin Spade Terminals)
Pilot Assemblies, CE and Export
806-8688SP Natural Gas with Thermocouple (Co-axial Lead)
106-1911 Natural Gas, Australian (Co-axial Lead)
806-8689SP Pro./But. Gas with Thermocouple (Co-axial Lead)
106-1912 Pro./But. Gas, Australian (Co-axial Lead)
Burner Heat Shield Assemblies
7 823-5295
Filter Burner Position, Left (includes bracket, 210-9729)
823-5296
Filter Burner Position, Right (includes bracket, 210-9729)
823-0574
Non-lter Burner Position (includes bracket, 930-0075)
826-2109
Kit, Retrot Filter Lid (includes 823-5295 and 823-5296, see Page 2-29)
826-2110
Kit, Retrot Filter Lid, LH Spreader (includes 823-5295, see Page 2-29)
826-2111
Kit, Retrot Filter Lid, RH Spreader (includes 823-5295, see Page 2-29)
8
Thermopile/Thermocouple
810-2007 Pilot, Thermopile, Natural Gas
810-2022 Pilot, Thermopile, LP Gas
807-3485 Thermopile, Generator with Adaptor
810-1873 Thermopile 1TT (Non-CE Pilot Assemblies)
9 810-0705
Tube, Pilot Gas (Use with all burner assemblies except Hong Kong export units.)
812-0278
Tube, Pilot Gas (Use with Hong Kong export units only.)
10
Gas Valves, Non-CE (see note below)
807-1603 mV Natural Gas
807-1604 mV Propane Gas
807-3294 24V Natural Gas (for 240V, use 807-0025)
807-3295 24V Propane Gas (for 240V, use 807-0759)
810-0786 E. I. Natural
810-0787 E. I. Propane
* 810-0691 Tube, Vent
NOTE: A gas valve capacitor (P/N 806-4781) is required on gas valves used on units with thermostat controllers.