Frymaster D20 Series Fryer User Manual


 
DECATHLON SERIES GAS FRYERS (CE)
CHAPTER 3: INSTALLATION
3-7
3.5 Gas Connections (cont.)
4. To limit movement of the fryer, restraints independent of the flexible coupling or connector
must be used. Clips are located on the back panel of the fryer for the attachment of
restraints.
5. If disconnection of the restraint is necessary, the restraint must be reconnected after the fryer
has been returned to its originally installed position.
J. After hook up, bleed the gas line of air to ensure that the pilot light will ignite quickly and
evenly.
K. CE Standards: If the unit is to be installed with flexible coupling, use a commercial flexible
coupling certified as NF D 36123 (or other national standard) or a quick disconnect device
certified NF D 36124 (or other national standard).
3.6 Adjustments/Adaptation To Different Gases
WARNING
Qualified personnel MUST perform any adaptation, modification, or gas conversion,
if required. Failure to use qualified personnel will void the Dean warranty.
A. Proper operation of appliances requires operator to inspect the following adjustments in terms of:
1. Gas inputs and pressures.
2. Voltage and polarities of electrical power supplies.
B. Dean gas fryers are manufactured to use the type of gas and pressure specified on the rating
plate. When changing to a different gas, adaptation must be performed by qualified
personnel. Failure to use qualified personnel will void the Dean warranty.
WARNING
If gas odors are detected, the gas supply MUST be shut off at the main shut-off
valve, and the local gas company or authorized service agency contacted for
immediate service.