Frymaster D20 Series Fryer User Manual


 
DECATHLON SERIES GAS FRYERS (CE)
CHAPTER 3: INSTALLATION
3-10
3.6.2 Gas Conversion Procedures (cont.)
When converting from G20 (20 mbar) to G25 (25 mbar), or vice-versa, or G31 (37 mbar) to G31 (50
mbar), the following procedures apply:
? ? Check pilot-adjustment and adjust as necessary.
? ? Other adjustments are not necessary.
Conversion from one gas family to another (i.e. changing from natural gas to propane) requires
special components. Obtain the necessary components using the cross-reference in Section 3.8, Gas
Conversion Components.
Conversions can only be executed by qualified, factory-authorized personnel.
ON Button- Pilot Gas-flowOFF ButtonPressure flow adjustment
Thermocouple connectionPilot flow adjustment
Vent tube connection
Use the following component information to convert from natural gas to propane and vice-versa.
Natural Gas to Propane Components Propane To Natural Gas Components
REF DESCRIPTION REF DESCRIPTION
810-2400 Pilot orifice (16LP) 810-0811 Pilot orifice (26N)
810-2059
Burner orifice
(diameter: 1.51 mm)
810-2060
Burner orifice
(diameter: 2.40 mm)
New Rating
Plate
Contact factory at time of
conversion.
New Rating
Plate
Contact factory at time of
conversion.
Burner orifices listed are for fryers operating at altitudes of 610 meters or less. For
altitudes greater than 610 meters, contact the factory for the correct orifice size.
CE Gas Valve