Frymaster D20 Series Fryer User Manual


 
DECATHLON SERIES GAS FRYERS (CE)
CHAPTER 3: INSTALLATION
3-9
3.6.1.2 Adjustments to Different Gas Types (cont.)
NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes
after the appliance is operating.
* For controls and adjustments, please refer to "gas valve" illustration on page 3-10. (Pilot Flame
Adjustment: Turn the pilot adjustment screw clockwise/counter-clockwise until the desired flame-
volume is achieved).
3.6.2 Gas Conversion Procedures
DANGER
This appliance was configured at the factory for a specific type of gas. Converting
from one gas type to another requires the installation of specific gas-conversion
components.
Switching to a different type of gas without installing the proper conversion
components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A
GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!
Conversion of this appliance from one type of gas to another should only be
performed by qualified, licensed, and authorized installation or service personnel, as
defined in Section 1.7 of this manual.
See page 3-10 for gas valve illustration when performing the following conversions.
When converting from G20 to G25 gas, the following procedures apply:
? ? Equipment replacement is not required.
? ? Adjust orifice gas pressure to the appropriate value listed in the tables on page 3-8 by
turning the gas valve "adjustment screw".
? ? After adjustment, replace the adjustment-screw cover.
When converting from G20 (or G25) gas to G31 propane (or vice-versa), the following procedures
apply:
? ? Burner orifices and pilot orifice MUST be replaced.
? ? Adjust orifice gas pressure to the appropriate value listed in the tables on page 3-8 by
turning the gas-valve adjustment screw.
? ? After adjustment, replace the adjustment-screw cover.
? ? Factory MUST be notified so the conversion can be documented and a new rating plate can
be sent out.